Cathodic Protection & Subsea Corrosion Engineering
Electrochemistry engineered to keep steel in warm, saline, high-oxygen GCC waters.
Warm, highly saline and well-oxygenated Gulf and Arabian Sea waters are aggressive to carbon steel. Cathodic protection, in combination with coatings, is the primary defence for jackets, pipelines, jetties, sheet-pile walls, intake structures and mooring systems. Marine Trex provides CP engineering from initial design through survey, assessment and retrofit.
Our approach links measurement to engineering. Potential surveys, anode depletion measurements and coating breakdown observations are fed back into CP design calculations to determine remaining protection life, identify under-protected zones and specify retrofit anodes or impressed current systems before steel loss becomes structural.
Scope of services
CP systems
- Sacrificial (galvanic) anode system design: aluminium and zinc alloys
- Impressed current cathodic protection (ICCP) design and commissioning
- Retrofit anode sleds and clamp-on anodes
- Transformer-rectifier and reference electrode monitoring
Surveys & assessment
- ROV-based and diver cathodic protection potential surveys
- ROV-mounted CP probes: proximity and field-gradient
- Anode condition and depletion assessment
- Corrosion potential measurement and mapping
- Coating inspection and breakdown assessment
Integrity & consultancy
- Subsea corrosion monitoring: probes, coupons and installed sensors
- Subsea pipeline integrity and CP effectiveness
- Anode remaining-life assessments and retrofit design
- CP engineering consultancy and design review
How we carry it out
01CP design
Current demand is calculated for initial, mean and final polarisation phases using surface area, coating breakdown factors and design current densities appropriate to the water temperature and depth, then anode mass, number and distribution are selected for the design life.
02Potential surveys
Steel-to-electrolyte potentials are measured against Ag/AgCl reference electrodes by contact (stab) probes at structural nodes and along pipelines, or by continuous ROV field-gradient surveys for buried and coated lines.
03Anode assessment
Remaining anode dimensions are measured and compared with as-installed mass to estimate depletion rate and remaining life; anode output is evaluated where field gradients are available.
04Corrosion mapping
UT thickness grids, potential maps and visual coating ratings are combined to locate active corrosion, often at the splash zone and at under-protected or shielded areas.
05ICCP engineering
Anode placement, reference electrode locations and rectifier sizing are designed to deliver uniform polarisation without overprotection or interference with adjacent structures.
Equipment and methods
- Ag/AgCl reference electrodes and contact CP probes
- ROV-mounted field-gradient CP systems
- Data-logging multimeters and potential loggers
- UT thickness gauges for corrosion mapping
- Coating thickness and holiday detection instruments (for accessible surfaces)
- Corrosion probes and coupons
Equipment listed describes the technology used to deliver this service. Specific systems are selected for each project's requirements and site conditions.
Specifications and standards
- Protection criterion
- Typically −0.80 V vs Ag/AgCl/seawater or more negative for carbon steel (confirm against governing standard)
- Overprotection limit
- Assessed for high-strength steels susceptible to hydrogen embrittlement
- Anode materials
- Al-Zn-In and Zn alloys selected for temperature and environment
- Survey modes
- Contact stab, continuous trailing-wire, field-gradient
- Assessment
- Remaining life of CP system vs required asset life
Relevant codes, standards & guidance
- DNV-RP-B401 Cathodic protection design
- ISO 15589-2 Cathodic protection of offshore pipelines
- ISO 12473 General principles of CP in seawater
- ISO 13174 CP of harbour installations
- EN 12495 CP for fixed steel offshore structures
- AMPP (NACE) SP0176 Corrosion control of submerged steel structures
- ISO 12944 / NORSOK M-501 protective coatings
The governing standards, survey orders and acceptance criteria are confirmed for each project against the client's specification and the applicable national requirements.
Deliverables
- CP design reports and calculations
- ICCP design, drawings and commissioning reports
- CP survey reports with potential profiles and maps
- Anode condition and remaining-life assessments
- Corrosion mapping and coating condition reports
- Retrofit recommendations and specifications
- Corrosion monitoring data reports
Where it is applied
- Ports and harbours
- CP design, survey and retrofit for steel piles, sheet-pile walls and jetties in warm, saline water.
- Offshore oil and gas
- Jacket and pipeline CP surveys, anode depletion assessment and retrofit design for life extension.
- Desalination and power
- Corrosion protection of intake structures, screens and seawater pipework.
- Marine infrastructure
- Protection of submerged steel and reinforced-concrete elements on bridges, outfalls and marine terminals.
Questions and answers
What is the difference between sacrificial anode and impressed current systems?
Sacrificial (galvanic) systems use aluminium or zinc alloy anodes that corrode in preference to the steel and need no power supply. Impressed current (ICCP) systems use a rectifier and inert anodes, which suits large structures and retrofits but needs power and monitoring.
What potential indicates that steel is protected in seawater?
The commonly applied criterion for carbon steel in aerated seawater is a potential of −0.80 V or more negative, measured against a silver/silver chloride/seawater reference electrode. Limits on over-protection also apply, particularly for high-strength steels.
How is an ROV CP survey carried out?
The ROV takes contact potential readings with a CP probe at anodes and bare steel, and field-gradient measurements along pipelines to assess anode output. Results are compared with design values to estimate remaining anode life.
Why is corrosion more demanding in GCC waters?
High water temperature, high salinity and heavy marine growth increase current demand and anode consumption, so designs and survey intervals should use regional design values rather than temperate-water assumptions.
Related expertise
- Advanced Subsea Engineering & Asset IntegrityCP readings are taken during ROV and diving inspection to share mobilisation.
- Specialized Marine Monitoring & TechnologyPermanent reference electrodes and corrosion sensors provide continuous CP status.
- Industrial Marine & Offshore ServicesRetrofit anode installation and coating repair are executed by our offshore teams.
- Marine Navigation & Offshore InfrastructureProtecting buoy hulls, moorings and SPM components from accelerated corrosion.